Posts

Immediate opening for an entry level lab assistant in the biotechnology

Image
On Assignment Lab Support has an immediate opening for an entry level lab assistant in the biotechnology industry for the Greater Dayton, Ohio area.. This is a perfect opportunity for a new grad to start their career! Duties will include specimen sampling, data entry, data management, writing reports, as well as, using aseptic technique, PCR, prepping biological samples, and more. Interested and qualified candidates should apply by sending resume, availability to interview, and contact information to cincinnati@labsupport.com. Required skills: AS or BS in biology, biotechnology, MLT, or a like science. Good computer skills! LOCAL DAYTON AREA CANDIDATES ONLY Pay starts at $9 - $12/hr Contact: Cincinnati Lab Support Job Type: Temporary / Contract Project Job Status: Full Time Locations: Multiple Locations Ohio-Dayton Ohio-Cincinnati Categories: Biotechnology Apply

Polymer Research Technician, Lancashire, Kelly Scientific UK

Image
* Job Role: Polymer Chemistry * Job Hours: Full-Time * Sector: Industry * Location: Lancashire * Company: Kelly Scientific UK * Salary: £22K-£25k * Job reference: P1542 * Posted Date: 03 May 2011 17:35:42 looking for a skilled Polymer scientist to assist with routine polymer analysis and development to join their research and development team. The ideal candidate will come from a polymers based background with experience within polymer characterisation and polymers based formulation. Analytical experience within GCMS, FTIR, LC AND DSC will be of help and candidates should ideally be educated to HND level or have equivalent experience. For more information on this role please contact Sebastian Mariner on 0161 839 2400 quoting reference P1542SEM APPLY

Filtering a precipitate from a solution

Image
Filtering a solid out of a liquid is done using filter paper and a filter funnel. The filter funnel is supported by the ring on a ring stand. Lay a clay triangle across the ring, then place the filter funnel into the triangle. filter paper To prepare the filter paper, fold the paper in half , then fold it in half again. When you look at the open edge of the folded paper you will see four edges of paper. With thumb and finger, catch three of these edges. Squeeze the sides of the folded paper and a cone will form with three thicknesses of paper on one side and one thickness of paper on the other. Place this cone of paper into the filter funnel. Place a "catch container" under the stem of the filter funnel and adjust the height of the ring on the ring stand until the tip of the stem is below the mouth of the container. Use a wash bottle and wet down the inside of the filter paper. This will help it stick to the funnel. You are now ready to filter. Carefully pour the liquid ...

Using a laboratory burner

Image
Many chemistry experiments require something to be heated. This is done with one of several types of laboratory burners. The lab burners at Mt. Lebanon High School use methane gas delivered through the gas outlets at student lab stations. a proper lab burner flame Before attempting to light any lab burner, check to see that the jet hole between the base and the burner tube is free of obstruction. If chemicals have covered this jet, the burner will not operate properly. After attaching the hose to the gas outlet, turn the handle on the outlet parallel to the nozzle to open the gas valve. The gas valve is turned off by turning the handle 90 degrees in either direction. Carefully check to see that you hear gas escaping from the mouth of the burner tube. When you are sure that you have gas, bring the head of the striker over the burner and squeeze the striker handle. The spark produced will ignite the gas and your burner is lit. Adjust the air control vent so that the flame has the proper...

Measuring mass with a triple-beam balance

Image
The triple-beam balance was once the "standard" balance in the general chemistry lab. While the electronic balance has replaced it in many cases, good science students should be familiar with the triple-beam balance and how to read one. a triple-beam balance The balance is named for its three "beams". An object is placed on the pan of the balance and tares on the beams are moved to balance the mass. As you face the balance, the back beam is graduated in 10 gram steps and the middle beam is graduated in 100 gram steps. It is very important that the tares on these two beams are in the notch for the whole number of grams and not in between notches. The front beam is a sliding scale graduated in grams. The tare on this beam can be positioned anywhere on the scale. Masses on a triple-beam balance can be read to tenths of a gram, and estimated to hundredths. Clicking on the balance picture will give you a close view of the position of the tares on the three beams. What m...

Measuring mass with an electronic balance:

Image
The electronic balance has many advantages over other types of balance. The most obvious is the ease with which a measurement is obtained. All that is needed is to place an object on the balance pan and the measurement can be read on the display to hundredths of a gram. an electronic balance A second advantage, using the Zero button on the front of the balance, is less recognized by beginning science students. Because one must never place a chemical directly on the balance pan, some container must be used. Place the container on the balance and the mass of the container will be displayed. By pressing the Zero button at this point, the balance will reset to zero and ignore the mass of the container. You may now place the substance to be weighed into the container and the balance will show only the mass of the substance. This saves calculation time and effort. However, when the container is removed from the balance, the display will go into negative numbers until the Zero button is pres...

Measuring the volume of a liquid with a pipette

Image
Pipettes are much more accurate than graduated cylinders. Reading the volume of liquid in a pipette is just like reading a graduated cylinder, however there is one additional technique needed with a pipette. The diameter does not allow a liquid to be poured into a pipette - the liquid must be drawn into the pipette. regular bulb on top and safety bulb on bottom This picture shows two of several types of pipette bulbs used to draw a liquid into a pipette. The red bulb is known as a standard pipette bulb. The black bulb is known as a safety pipette bulb. Much of the "professional" lab work today is done with automatic pipettes. These are expensive little gadgets that come in many different volumes, each delivering exactly its assigned volume with one click of a button. High school chemistry students need to know the basic techniques of pipetting, so you will be using glass pipettes and the standard pipette bulb. The standard pipette bulb requires manual dexterity that is imp...